Prey Limited - Complete Equipment Brochure - Flipbook - Page 19
Technical Specifications - Harrier 6
Maximum PCB Width
Standard: 450mm
Number of Heating Zones
Top: 6 Zones and Bottom: 6 Zones
Number of Cooling Zones
Top: 2 Zones and Bottom: 2 Zones
Heating Area Lenth
2,300mm
Cooling Area Length
685mm
Cooling Method
Water Chiller Cooling
Temperature Accuracy
+/- 1℃
Temperature Uniformity
+/- 2℃
Transfer Method
Center Board Support
PCB Flow Direction
Rail plus Belt System
Optional
Left To Right As Standard (Optional Right To Left)
Conveyor Height
900 +/-15mm
Conveyor Speed
400 ~ 2,000mm/min
Control Method
Windows Based PC Controls
Temperature Control
PID Temperature Controller
Temperature Control Range
Room Temperature ~ 300℃
Heat up Time
30 Minutes
Total Power
59KW
Startup Power
25KW
Operating Power
9KW
Built In UPS
Included As Standard
Flux Management
Included As Standard
Hood Lift
Process Data Storage
Alarm System
O2 Analyser
Exhaust Requirements
Air Pressure
Power Supply
N2 Consumption
Machine Dimensions
Machine Weight
Electrical Cylinder
Manual-save Process Data, Auto Save Operation Record
Temperature & Speed Deviation, Blower Failuer, Dropped Board
Standard: O2 Analyser + N2 Flow Meter + N2 Pipe
>10m3/min x 2 Exhuast Port
5 ~ 7 KG/cm³
3 ∮ 380 V, 50 Hz
25 m³/h @ 500~1000ppm
4,350mm x 1,420mm x 1,520mm
2,850KG